CASE DIAMETER 100 or 150 mm
ACCURACY Class 1
SCALE RANGES From 0...0.6 bar to 0...1600 bar (or similar in other pressure units)
PRESSURE LIMITS DURING OPERATION Continuously: steady pressure up to F.S. value, fluctuating pressure 90% of F.S. value Temporarily: 1.3 x F.S. value for ranges up to 60 bar or 1.15 x F.S. for ranges from 100 bar to 1600 bar
TEMPERATURE LIMITS Ambient: -40 to +60 °C (without liquid filling) and -20 to +60 °C (with liquid filling) Process: maximal fluid T° is 200 °C (without liquid filling) and 100 °C (with liquid filling)
DRAFT DUE TO THE TEMPERATURE When the measuring system T° is different from the reference T° (+20 °C) the draft is 0.4% / 10 K of true scale value, as a maximum.
TECHNICAL FEATURES
PROCESS CONNECTION Stainless steel: AISI 316 L – Thread 1/2” BSP or NPT – M20 x 1.5 Lower or back mounting
PRESSURE ELEMENT Stainless steel: AISI 316 L < 100 bar : C - type > 100 bar : Helicoidal type
MOVEMENT Stainless steel: AISI 316 L
DIAL White, black marks Graduated scale length 270° angle
POINTER Black aluminium pointer, adjustable
CASE AND RING Stainless steel: AISI 304 Pressure relief disc (25 mm ∆) on the back Filling plug on the top (used as a vent hole for ranged instruments up to 16 bar) Bayonet type ring
WINDOW Safety glass 4 mm thick
SEALING Neoprene gasket
INGRESS PROTECTION IP 65 acc. EN 60529 / IEC 529
OPTIONAL EXTRAS Other connection types – Case and ring AISI 316 L – Front or rear flange Silicone oil case filled (ambient temperature from -40 to +60 °C); other filling liquids on request – Electric contacts – Diaphragm seals – Oxygen application: grease free measuring system – Scale in °C for cooling fluids Accuracy class 0.6 – ATEX certification Ex II 2 GD c – Accessories.