Warning! You are consulting an archived documentation:
This product is not anymore manufactured or marketed by BAMO
Do not hesitate to contact us if you are looking for a substitution product certified or if you have a question
Heavy duty service
Output signal: 4-20 mA (0…5V & 0…10 V on request)
Accuracy 0.5% (0.25% on request)
Scales from -1 bar to 1 000 bar
DESCRIPTION
Accuracy, reliability, corrosion resistance and vibration level acceptance allow the use of these high performance transmitters in environments of factories, workshop, development laboratories.
Scale ranges are in conformity with EN standard. Body and wetted parts are in stainless steel for chemical compatibilities. Two potentiometers allow zero and span adjustments in case of extreme measuring conditions (like with hydrostatic column). CE Mark: In accordance with EMC directives (EN 61326 – electronic magnetic compatibility).
TECHNICAL FEATURES
Ranges: Relative or absolute pressures
Process connection: 1/2” MG - DIN 16 288
Output signal: 4...20 mA – 2 wire
(on request. 3 wire: 0...5 V DC; 0...10 V DC)
Sensor: Piezo-resistive
Repeatability: ≤ ±0.05 % F.S.
Accuracy: ±0.5 % F.S. (on request: ±0.25 % F.S.)
Stability per annum: ≤ ±0.2 % F.S.
Overload limit:≤ 16 bar: x 3.5 ; ≤ 600 bar: x 2 ; > 600 bar: x 1.5
(x range max. value)
Electrical connection: Plug DIN 43 650
Body: Stainless steel
Power supply: 10...30 V DC
Power consumption:Current output 4...0 mA / signal currency
Current output 0...20 mA / signal currency + 4 mA
Voltage output / 8 mA
LOAD
Current output 0/4...20 mA: Load = [ (UB -12 V) / 0.020 A ]
Voltage output 0...5 V DC: Load > 5 kOhm
Voltage output 0...10 V DC: Load > 10 kOhm
Temperature compensation: 0...80 °C
Temperature influence:On zero point: ± 0.2 % /10 K
≤ ± 0.4 % / 10 K for scales 0…0.1 & 0…0.16 bar
On measuring range: ± 0.2 % /10 K
Adjustments:Zero & span within ± 10 %
Response time:≤ 1 ms within 10 to 90 % F.S.
Protection: IP 65 - EN 60 529 / IEC 529 (Connector. IP 67)
Electrical protection:Polarity overload and short circuit
Temperature limits:Ambient -20...+80 °C
Medium: -30 ... +100 °C (on request: -20...+125 °C)
Masse: 0.2 Kg
CE Mark:EMC directives (EN 61326)
Pressure equipment directives 97/23/EC
General Catalog 805-02 08/11/2018 10:46
Pressure transmitter Industry series
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France