This model CDV is designed for cooling circuit survey, or survey of any high pressure circuits, to protect pumps against flow less accidents.
PRINCIPLE
The fluid moves over an orifice plate with a built-in magnet. A compensating spring allows the mounting in any position. CDV operates without incidence of pressure on measurement, even with low flow rates. The diver indicates the flow rate through a graduated glass tube. A Reed contact is adjustable all along the scale. The contact is Normally Open (opened with flow less conditions).
TECHNICAL FEATURES
Pressure limits: Fittings 1/4" and 1/2" –> 16 bar
Fittings 1": 10 bar
Temperature limits: 0 to 100 °C (sealing NBR)
Scale unit : For water at 20 °C
Accuracy : ±10 %
Pressure drop: 0.02 to 0.4 bar (acc. F.S.)
Contact: N.O. (Switching power: refer to next page)
Hysteresis: ≈1.5 mm
Connector: DIN 43650 - IP 65
Transparent tube: DURAN® 50 glass tube
Magnet: Ferrite
Brass version
Body: Aluminium alloy, anodized
Fittings, orifice plate: Brass
Seals: NBR
Spring: Stainless steel 304
Stainless steel version
Body: Aluminium alloy, anodized
Fittings, orifice plate: Stainless steel 316 L
Seals: FPM
Spring: Stainless steel 304
General Catalog 722-02 17/04/2018 11:45