Search
MENU Catalog Global Sites
BAMO
FRANCE
French manufactured of sensors and control instruments for fluids
You are actually in BAMO EN » Our Products » General Catalog » Turbidity » TRUBOMAT® GAB
General Catalog 446-01
TRUBOMAT® GAB
TRUBOMAT® GAB
In line turbidity transmitter
TRUBOMAT® GAB
TRUBOMAT® GAB
  • Stainless steel in-line turbidimeter according to ISO 7027
  • Turbidity transmitter
  • With two IR emitters and one IR receiver
  • Two models: 0.01...20 FNU (5 ranges)
    0.1...1000 FNU / FAU (5 ranges)
  • 4...20mA output signal (4 wires)
  • Flange or triclamp or  connections
PRINCIPLE

The TRUBOMAT measures the turbidity of liquids using the light absorption and scattered light measuring method. The inline measuring cell includes two IR emitters and one IR receiver in pulsating light mode (IR measuring method according ISO 7027).When interconnected, the BAMOPHOX TUR, measuring amplifier, analyses the 4 to 20 mA signal generated by the TRUBOMAT.

DESCRIPTION
The flow-through cell allows the turbidity measurement directly on the line, without sampling system. Its built-in transmitter is convenient for transmitting the signal to installed DCS or PLC or BAMOPHOX TUR. The 4-20 mA corresponds to the DIP Switch selectable range: 
 
TRUBOMAT 20: from 0.01 to 20 FNU in 5 selectable ranges
TRUBOMAT 1000: from 0.1 to 1000 FNU / FAU in 5 selectable ranges
APPLICATIONS

• Drinkable and waste water plants, well water monitoring
• Filtration control, flocculants dosage, phase separation
• Pollution survey

TECHNICAL FEATURES
Power supply: 24 V DC rated (10...30 V DC) 
Power consumption: 0,5 W
Output signal: 4-20 mA, for connection to the BAMOPHOX TUR 436
Ambient temperature: +5...+45 °C
Process temperature: +5...+100 °C
Material: 316L Stainless steel body / Terminal housing plastic PBT, IP 65
Accuracy: ±5% reading, ±1% full scale in use
Resolution: 0,001...0,2 FNU according to measuring range

Status indication: Green LED = correct
Red LED = failure

Selectable ranges TRUBOMAT 1000:
0.1 to 50 FNU
0.1 to 100
0.1 to 200
0.1 to 500 (or 0.1 to 300*) FNU
100 to 1000 FNU
* fittings DN80 & DN100

Selectable ranges TRUBOMAT 20:
0.01 to 1 FNU
0.01 to 2 FNU
0.01 to 5 FNU
0.01 to 10 FNU
0.01 to 20 FNU
* fittings DN80 & DN100

Material: Stainless steel body

Process connections:
PN10 flanges (DIN 2633), Triclamp (DIN 11850)

CE Mark:
In accordance with low-voltage directive (2006/95/EG), EMC directives (2004/108/CEE)

General Catalog 446-01
17/04/2018 10:58
In line turbidity transmitter
TRUBOMAT® GAB
Technical & Commercial support's main contacts
Ask a QUOTATION online
BAMO Mesures SAS
22, Rue de la Voie des Bans
Parc d'activités de la Gare
95100 ARGENTEUIL France
Tel: +33 1 30 25 83 20
Fax: +33 1 34 10 16 05
E-mail: export@bamo.fr
URL: http://www.bamo.fr
Siret: 314 055 864 000 65
TVA Intra: FR 08 314 055 864
APE: 2651 B
Capital: 400 000 Euros
Built by CARIMEDIA since 1998
© 1998-2024 All rights reserved - Disclaimer