Scales in water: 2.5 to 63000 L/h in air: 0.08 to 1000 Nm3/h
Threaded or flange connections
Options: LCD digital display for flow rate and totalization Hart protocol, 4-20 mA output 1 or 2 adjustable alarm contacts ATEX certification, EEx ia IIC T6 / EEx d IIB T4
DESCRIPTION
These flow-metres are designed for gases. Viscosity variations have less effect on results thanks to a specific profile of the diver. The transmission of the diver position to the display is magnetically operated. The small distances between the connections allow an easy location in a small volume. A dumper option is available for low nominal pressures where pulses on pressure could affect the accuracy. As options there are a transmitter 4-20 mA two wires model and alarm contacts. For ATEX area, two versions are certified, intrinsically safe EEx ia and explosion proof EEx d.
PRINCIPLE
For a correct operation, the flow must be vertical and upward. The gas passes through a diaphragm pushing a conical. The diver position is at the equilibrium point between the kinetic energy due to the speed of the fluid and the diver weight, profile and diaphragm geometry. - Each balance point corresponds to a flow rate value. - Flow rate transmission is done with a magnetic transmission.
TECHNICAL FEATURES
Indicator with or without alarm contacts (standard)
Scale range: 1 to 10 Analogical scale length: 80 mm Accuracy: +/- 1.5% full scale (standard) Repeatability: 0.5% full scale Maximal pressure: 40 bar (higher pressures on request)
Temperature limits: -10 ... +150°C without alarm contacts -10 ... +100°C with alarm contacts -30 ... +300°C high temperature version (with and without alarm contacts)
Process connections: Flanges PN 16 UNI 2223/29 (standard); threads BSP, NPT, Triclamp Wetted parts: Stainless steel 316 L, PTFE – on request: Titanium, Hastelloy C Display housing: Cast aluminium, epoxy painted RAL 7001 Protection: IP 67 OPTIONS: Inductive contacts (adjustable all along the scale) with 8 V CC power supply
Indicator with transmitter
Scale range: 1 to 10 Analogical scale length: 80 mm Accuracy: +/- 1% full scale (standard) Repeatability: 0.5% full scale Programmable display: LCD, 8 digits (flow rate, %, totalization) Response time: < 0.5 s (only the electronic) Analogical output: 4-20 mA, 2 wires Hart protocol transmission: optional Main power: 24 V DC +/-10% Alarm contacts: optional, 1 or 2 adjustable contacts Maximal pressure: 40 bar
Temperature limits: -10 ... +90°C without alarm contacts -10 ... +90°C with alarm contacts -30 ... +300°C high temperature version (with and without alarm contacts)
Process connections: Flanges PN 16 UNI 2223/29 (standard); threads BSP, NPT, Triclamp Wetted parts: Stainless steel 316 L, PTFE – on request: Titanium, Hastelloy C Display housing: Cast aluminium, epoxy painted RAL 7001 Protection: IP 67
OPTIONS: ATEX Certification EEx ia IIC T6 (Intrinsically safe) ATEX Certification EEx d IIB T4 (Explosion proof)
General Catalog 742-01 17/04/2018 11:49
Variable area flow metre C6/C5-250
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France