Warning! You are consulting an archived documentation:
This product is not anymore manufactured or marketed by BAMO
Do not hesitate to contact us if you are looking for a substitution product certified or if you have a question
ATEX certification II I G EEx ia IIC T6 IP6X T° 70°C
Zones 0, 1, 2 (gas)
For agressive liquids
TECHNICAL FEATURES
Operation mode: Omni-directional Allowed fluid density: 0,80 to 1,10 Maximal pressure: 4 bar Service T° & storage: T6 i.e. from - 20° to + 70° C Protection index: IP 6X
Power supply: 24 V AC / V DC – 10 mA 12 V AC / V DC – 100 mA
To be connected to:intrinsic safety amplifier relay, ATEX certified only
Standardized cable: HR-HY (HYPALON) H07RN8-F 3 wires x 1 mm2
Weights: Float = 300 g - Cable = 110 g/m Adjustable ballast on cable: Loaded resin 250 g (included) Standard cable lengths: 5 & 10 m (other on request)
For use in potentially explosive areas classified 0, 1 and 2 (gas), in conformity with standards:
EN 50014 (1992) - NF EN 50014 (1993) - EN 50281-1-1 (1998)
EN 50281-1-2 (1998) - EN 50020 (1994) - NF EN 50020 (1995)
Highly explosive zones EEx ia Group IIC Certification: LCIE 00 ATEX 6003 X of 15/February/according to directive 94/9/CE.
CONNECTION for EEx zone 0,1 and 2, absolute necessity to use an intrinsic safety amplifier relay with ATEX certification, which must not exceed:
Li ≤ 2 mH et Ci ≤ 203 jF with 2 m of cable length U0 ≤ 30 V - I0 ≤ 100 mA - P0 ≤ 0,75 W No respect of these limits will destroy the gold plated contacts. All connections will be performed according to the Low Voltage Directive and Intrinsic Safety instructions.
General Catalog 521-01 17/04/2018 15:46
Float level indicators for EEx zones SSX
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France