Warning! You are consulting an archived documentation:
This product is not anymore manufactured or marketed by BAMO
Do not hesitate to contact us if you are looking for a substitution product certified or if you have a question
pH or ORP configurable
Universal and programmable
Controlled by microprocessor
Alphanumeric displayer
Display back lighted LCD
Simultaneous Measure / Temperature display
Ranges: programmable 0 - 14 pH, ± 2000 mV
Compensated temperature Automatic by Pt 100 Ω probe or Manual
Two 0/4 - 20 mA analogic output, galvanically isolated and configurable Ouput 1: Measurement Ouput 2: T°C or PID regulation
3 relay outputs: 2 adjustables alarm with switching output or proportional regulation 1 temporized output alarm or self cleaning
1 regulation input
Housing Enclosure box 72 x 144 BAMOCOR 321 E Wall mounting IP 65 BAMOCOR 321 M
OPTIONS J-Bus communication RS 422 or RS 485 digital links 348 000 measures data logger Electromagnetic pump start
DESCRIPTION
The BAMOCOR series are easy-to-use microprocessor based controllers. Calibration and configuration is as easy as pushing a button. Calibration and configuration is done by a simple step-trough menu for all settings. A single 16 alphanumeric characters back lighted LCD display is used to indicate the measures and temperature. It displays also the menu for the allocation of sets, the adjustment of the analog output, as well as all function modes. Analog output 4-20 mA is galvanically isolated and can be set over the measured range. These versions of our pH / mV meters allows to solve all problems of measure with or without automatic temperature compensation, more a RS 422 output module is available for communication between a computer and the BAMOCOR 105 including J-BUS protocole.
TECHNICAL CHARACTERISTICS
Displayer : 16 alphanumeric characters - H = 9.22 mm - Back lighted Visualization: Red leeds of relays functions, located on front panel. Programmation: On front panel with 5 push-button keyboard - Password protected keyboard Measure range: pH-meter configuration: 0 up to 14 pH - mV-meter configuration: ± 1000 mV Accuracy: Measure: ± 0,3 % - Temperature: ± 0,3 °C Input probe: >1013 Ω - Connection by 9054 coaxial connector
Compensation T °C: Automatic: By Pt 100 Ω probe on a scale, 0 up to 100 °C Manual: According to the working temperature choice, 0 up to 100 °C
Output relays: 3 Volt free change over contact rated at 500 VA / 250 V / 2 A Alarmes sets: 2 independants alarm sets - Adjustable Hysteresis, 0 up to 100 % - Adjustable timer 0 à 9999 sec Output relay default: For too long injection - Adjustable timer 0 to 9 999 s. Pulsing regulation: Setting of cycle time, 0 up to 9999 s, high and low proportional bands, High and low dead zones. P.I.D. regulation: Adjustable proportionality, 0 up to 200 %, adjustables Integrale and Derived, 0 up to 999 secondes Testing phase: Neutralization of output switching, storage the last analogic output values. Self cleaning programme : Programming of cycles time and cleaning, neutralization of switching output, storage the last analogic output values. Measure output: 0/4 - 20 mA (600 Ω max.) Proportional at measure - Galvanic insulation included Temperature / PID output: 0/4 - 20 mA (600 Ω max.) On any range from 0 °C up to 100 °C - Galvanic insulation included Measurement simulation: By menu - Action on output measure, temperature, P.I.D.- Alarmes Main power supply: 230 VAC ±10 % 50-60 Hz single phase - Consumption, 10 VA (117 V, 48 V, 24 V on request) Enclosure box: Dimensions (mm): 72 x 144 x 185 - Weight : 1100 g Protect: IP 40, front panel IP 65 - Material: Noryl, polycarbonat front panel. Connection: Dismountable screwed connector Wall mounting box: Dimensions (mm): 355 x 237 x 95 - Weight : 1900 g Protection: IP 65 - Material: ABS, front panel polycarbonat Connections: Terminal screw, input by plastic cable gland. Temperature : Stockage: -10 up to 70 °C - Functioning: -5 up to 50 °C
OPTIONS (not cumulable)
Communication: J-BUS connection - Slave binary mode - RS 422 or RS 485 - 1200 up to 9600 bauds Electromagnetic pump: 50 up to 120 pulses /mn - Reed relay type - P.C. 100 VDC / 0,5 A / 10 VA - impulses 250 ms Logger: Averaged automatic registrement of measure in programmed interval.
Maximum registrements number: 348 000 (Exemple: 1 minute during = 6 months datas) Memory is automatically cleared after datas transfer to computer.
LOGGER & CORLOG
logger option is available at the ordering.This option will be to add on a 4.00 minimal software version of BAMOCOR. Devices not supporting this version must be replaced. For this option, each device is delivered with CORLOG interface (3.5" HD including the software for WINDOWS). This interface allows the dated treatment possible on standard softwares: Spreadsheet files or DataBase.
POSSIBILITY LOGGER option allows:
Uninterrupted automatic data-processing recording of measurements made by device. This saving function is always active, (no stop possibility).
Follow-up in real time of these measurements.
Connection with a standard computer (PC) CORLOG software allows: Automatic taking of recorded BAMOCOR values. When the Unloading program started, the datas will be transmitted and memory cleared
TESTLOG software installed with CORLOG allows the unloading of datas, without memory reset all, with possibility to make daily files with TESTLOG and a weekly file with CORLOG.
Creating a device spreadsheet files for datas treatment Example: Calculations, curves...
Until 4 BAMOCOR line control.
NECESSARY CONFIGURATION A computer PC compatible
Windows 3.1x, 95 or 98.
Serie communication RS 422 (or RS 232 with converter BAMOTOP 239 RS422 / RS 232 ).
Screen: SVGA 800 x 600, 65536 colors
Spreadsheet or DataBase software, for datas treatment.
DELIVERED UNIT The bamocor with its memory and RS 422 communication interface.
CORLOG & TESTLOG softwares on 3.5" HD.
CHARACTERISTICS pH / rH and Temperature measures automatic recording
Interval between 2 recordings: adjustable from 1 up to 60 minutes (average is made every second during interval).
Real time displaying * pH or mV measure * T °C measure
Maximum records numbers: 174 000
General Catalog 105-01 17/04/2018 15:39
pH-meter & ORP-meter BAMOCOR 105
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France