Protection for Reed contacts, Voltage free switches...
Change over switch output
DIN rail mounting, ABS housing
Intrinsic safety acc. EN 50014 / EN50020
APPLICATION
Amplifiers with galvanic insulated relay for protection of low voltage switch with intrinsic safety circuit in Ex area.
TECHNICAL FEATURES
Main supply: 230 V AC ±10% - 48/62 Hz 110 V AC ±10% (on request) 24 to 48 V DC ±10% (on request)
Front signalization: Green LED when power is ON Consumption: 4.5 VA or 1.6 W Input signal: (from Ex area) Voltage free contact Output signal: (to safe area) Change over contact, 250 V, 5A, 100 VA as a maximum Response time: 20 ms (relay), 100µs (transistor) Switch frequency: 10 Hz as a maximum. Front red LED is lighting when corresponding relay output is energized or when output transistor is "ON" Galvanic insulation: Between Input / Output / Supply Alternative current supply: 2500 V AC - 50 Hz Direct current supply: 2500 V AC - 50 Hz
MECHANICAL DATA
Installation: In safe area Housing: ABS Net weight: 200 g Storage temperature: -25 to 70°C Operating temperature: 0 to 60°C Ambient: 5 to 95% HR, no condensing Connections: Plug-in clamp terminals Mounting: DIN rail EN 50022 Configuration: Input and function through switches
STANDARDS and CERTIFICATES
EMC: Immunity EN 50082-2-1995, Emission EN 50081-2-1993
Low Voltage Directive: IEC 1010-1 Category II (over voltage) Intrinsic Safety: EN 50014 / EN 50020 (EEx ia) IIC LCIE certificate n°: 02 ATEX 6104 X Certification: ATEX Ce0081 Ex II (1) G/D
PROCESSING
When the contact is closed between J and H in EX area, the relay DEF status changes, then the circuit EF is closed (F = neutral).
General Catalog 251-01 17/04/2018 10:44
Threshold amplifier, intrinsic safety RDN 11
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France