A PVDF turbine with PTFE axis rotates proportionally to the fluid speed. The fluid is injected through an injector of various diameters to allow different ranges. Permanent magnets are inserted in the turbine to actuate a Hall Effect sensor. A frequency-squared signal is proportional to the fluid speed and to the real flow rate.
APPLICATIONS
Designed for low flow rates, the FFG flow metre is reliable in all industries for neutral or very aggressive liquids. The FFG accepts no crystallizing fluids and without particles. It is better to install a filter before the flow metre.
TECHNICAL CHARACTERISTICS
Range: 6 to 720 L/h (water at 20°C), depending of nozzle diameter
Accuracy: ± 1% full scale for 1:10 ratio range ± 2% full scale for 1:25 ratio range
Repeatability: > 0.25 % Temperature: Ambient 0 ... +40°C Pressure: vs. temperature, see the drawing Viscosity: 0.2 to 20 cSt Housing: PVDF, Polysulfon or Arnite (PBT) Turbine: PVDF Nozzle: PTFE Turbine axis: PCTFE O-ring: FPM Power input: 5 to 24 V DC Consomption: 5 to 13 mA as a maximum Output signal: NPN collector – Signal load, max. 20 mA Connection: IP65, DIN 43650 connector
Cable: 3 x 0.75 mm2 shielded - max. length: 100 meters 3 x 0.75 mm2 without shield - max. length: 30 meters
Process connection: BSP 1/4" Weight: 185 g
General Catalog 784-01 17/04/2018 11:57
Turbine flow-metre FFG
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare