-Universal and programmable -Controlled by microprocessor -Alphanumeric displayer -Display back lighted LCD -Simultaneous Mesure/Température display -Measure range 0 - 200 Ohm up to 0 - 200 MOhm or0 - 2 µS up to 0 - 20 mS or0 - 20 mS up to 0 - 2000 mS /TOR version -Automatic/manual compensated temperature -2 adjustables alarm with switching output -0/4 - 20 mA analogic output, isolated -Housing Enclosure box 72 x 144BAMOCOR 321 E Wall mounting IP 65BAMOCOR 321 M -Associated probes Coefficient : 10 - 1 - 0,1 - 0,01 TCS 100 TOR probe
OPTIONS - J-Bus communication RS 422 or RS 485 digital links - 348 000 measures data logger
DESCRIPTION
The BAMOCOR series are easy-to-use microprocessor based controllers. Calibration and configuration is as easy as pushing a button. Calibration and configuration is done by a simple step-trough menu for all settings. A single 16 alphanumeric characters back lighted LCD display is used to indicate the measures and temperature. It displays also the menu for the allocation of sets, the adjustment of the analog output, as well as all function modes. Associated probes can be set with coefficient of 0,01, 0,1, 1 or 10. These coefficients allow accurate measures between 20 Ohm up to 200 MOhm and in conductivity from 0,2 µS up to 20 mS. The analog output is galvanically isolated and can be set over the measured range. These versions of our conductivity / resistivity meters allows to solve all problems of measure with or without automatic temperature compensation, more a RS 485 2-wire output module is available for communication between a computer and the BAMOCOR 321.
TECHNICAL SPECIFICATIONS
Main power supply:230 V ±10 % 50-60 Hz single phase. (117 V, 48 V, 24 V on request) Consumption: 10 VA Enclosure box:Dimensions : 72 x 144 x 185 - Weight : 1100 g Protection: IP 40, front panel IP 65 - Material: Noryl, front panel polycarbonat Connection: Dismountable screwed connector Wall mounting box:Dimensions: 355 x 237 x 95 - Weight : 1900 g Protection: IP 65 - Material: ABS, front panel polycarbonat Connections: Terminal screw, input by plastic cable gland. Temprature:Stockage: -10 up to 70 °C Fonctionning: -5 up to 50 °C Measure range:Measure: 0 - 2 µS up to 0 - 20 mS or 200 Ohm up to 200 MOhm (0 - 20 mS, 0 - 200 mS, 0 - 2000 mS, /TOR Vers.) Temperature: 0 up to 100 °C Probes:Measure: Coaxial probe with K= 0,01 or K=0,1 or K=1 or K=10 or TOR probe (TCS 100) Temperature: Pt 100 Ohm à 0 °C, 3 wires system. Accuracy:Measure: ± 0,3 % - Temperature: ± 0,3 °C Displayer : 16 alphanumeric characters - H = 9.22 mm - Back lighted Input probe:BNC coaxial connector PIN type , or dismountable screwed connector (TOR version) S1 and S2 alarm sets:Volt free change over contact rated at 500 VA / 250 V / 2 A Current/Measure output:0/4 - 20 mA ( 600 Ohm max) proportional to measurement - Galvanic insulation included Communication:J-BUS connection - Slave binary mode - RS 422 or RS 485 - 1200 up to 9600 bauds Visualization:Red leeds of relays functions, located on front panel. Programmation:On front panel with 5 push-button keyboard - Password protected keyboard Simulation measurement: By menu - Action on output measures.
SELECTION OF THE MEASURING PROBE
The measuring range imposes a coefficient of the probe to work with optimum conditions to get good measures. Our technical service is at your disposal to guide you in the choice of the most appropriated probe. Coefficient of the selected probe will be allocated on the menu.
TEMPERATURE COMPENSATION
The BAMOCOR 321 allows an automatic or manual temperature compensation. The temperature affects the behaviour of the fluid itself and not the probe. The ionic dissociation is different in regard of the fluid the temperature and the measuring range. The variation of resistivity (conductivity) can change with small temperature variation. For example, with demineralized water (18 MOhms), the slope varies from 2% in low temperatures (5 to 10 °C) to only 0.5% between 80 and 90 °C. These variations are different for water with a high amount of salt. A universal and linear correction is therefore difficult. The BAMOCOR 321 allows an automatic or manual temperature compensation on 2 measuring ranges from 0 to 100 °C. Without temperature compensation 2, 3 or 4 measuring ranges are possible. Only the choice of the probe will determine the possible ranges according to its coefficient. (Refer to page 321/ 2) In case of over scale the meter displays the former by the symbol > 2 MOhm for a scale 0 to 2 MOhm selected in the programming. Manual The temperature will not be measured. The resistivity (conductivity) displayed will be therefore the only measure of the probe corrected with the assigned temperature 20 or 25 °C (selection on the menu). This application is available only when the temperature varies a few degrees. Automatic The temperature will be measured with a Pt 100 probe integrated in the conductivity cell or with a separate probe. The correction is made with the microprocessor between 0 and 100 °C on two measuring ranges according to the coefficient of probe. For specific applications our technical service can design a custom specific compensation.
CABLE CONNECTION
The choice of the cable is very important. The cable resistance and capacity can produce an measuring error up to 50%, typical on high resistivitys (low conductivities). Connection of the cable to the probe and the BAMOCOR wiring bare have to be made without any intermediate connection. The max. cable length is depending from the measuring range and the coefficient of the probe. Standard we supply shielded coax cable reference CCA (code 368 100), for some applications the type 9060 (code 160 300) is delivered for series BS 1200 measuring probes with 9054 connector. The measuring cable has to be separated from power cables and any other power sources for at least 20 cm, we advice to use separate cable glands. In case of crossing the measuring cable with power cables it is recommended to cross them in an straight angle to limit the interference.
LENGTH OF MEASURING CABLES
Conductivity Du to a specific electronic circuit to measure conductivity the cable can have a length of 100 m on all measuring ranges independent from the coefficient of probe. Resistivity According to the following table (max. length in meter).